CAM-LOCK
PERIMETER WALL
TO FLOOR
|
WALL TO FABRICATED FLOOR
 |
WALL AT RECESSED FLOOR
RECESS IN FLOOR SHOULD EQUAL
FLOOR THICKNESS - 4 1/4"
|
 |
CAM-LOCK PARTITION
WALL TO FLOOR
|
 |
|
|
WALL ON CONCRETE FLOORS
COOLERS  |
|
|
 |
|
 |
STANDARD SCREED
MEETS N.S.F. REQUIREMENTS
|
WALL TO FLOOR-INSULATED SLAB
FREEZERS
 |
OPTIONAL SCREED
P.V.C. CHANNEL SCREED
|
 |
OPTIONAL SCREED
2”
LOCKING P.V.C.
MEETS N.S.F. REQUIREMENTS
| Suggested Floor Insulation
        Expanded
Temperature (F)
Polystyrene Urethane
32 degrees to -20
6"
4"
Design based on interior installation in certain regions and
applications, it may be necessary to vent below insulated slab
to prevent heaving. |
|
 |
RECESSED WALL PANEL
WITH INSULATED WEAR SLAB
|
RECESSED
APPLICATIONS
 |
RECESSED FLOOR
WITH CONCRETE WEAR SLAB
|
 |
RECESSED FLOOR
WITH TILE
|
 |
STANDARD APPLICATION
CAM-LOCK PERIMETER
WALL TO TOP
|
TOP TO WALL
 |
CAM-LOCK PARTITION
WALL TO TOP
|
 |
ANGLE WALK-INS
 |
NOTE:
LAG
DOWN TOPS AND GRAVITY FLOORS ARE USED ON ALL ANGLE WALK-INS (WALK-INS
THAT ARE NOT SQUARE OR RECTANGLE
|
TOP TO PERIMETER WALL

LAG BOLTS ARE
USED TO
FASTEN TOP TO PERIMETER WALL |
TOP TO PARTITION WALL

LAG BOLTS ARE
USED TO
FASTEN TOP TO PARTITION WALL |
ALTERNATE TOP TO WALL

WHEN CLEARANCE ABOVE TOPS
DOES NOT ALLOW STANDARD LAG
DOWN APPLICATION. |
GRAVITY FLOOR
 |
|
TOP
SUPPORTED BY
BEAMS AND COLUMNS
|
TOP SUPPORT

 |
|
TOP SUPPORTED BY
EXTERIOR CHANNELS
|
 |
|
STANDARD SUSPENDED TOPS
12 GA WIRE IS FASTENED TO THE BUILDING STRUCTURE |


|
|
OPTIONAL SUSPENDED TOPS:
ALL THREAD ROD IS SECURED TO BUILDING STRUCTURE |
 |
TRIM DETAILS
 |